Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters

Database
Language
Document Type
Year range
2.
Microbiol Spectr ; : e0292222, 2022 Nov 21.
Article in English | MEDLINE | ID: covidwho-2137478

ABSTRACT

In keeping with the evolution of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the COVID-19 causative agent, PCR assays have been developed to rapidly detect SARS-CoV-2 variants, which have emerged since the first (Alpha) variant was identified. Based on specific assortment of SARS-CoV-2 spike-protein mutations (ΔH69/V70, E484K, N501Y, W152C, L452R, K417N, and K417T) among the major variants known to date, Seegene Allplex SARS-CoV-2 Variants I and Variants II assays have been available since a few months before the last (Omicron) variant became predominant. Using S gene next-generation sequencing (NGS) as the SARS-CoV-2 variant identification reference method, we assessed the results of SARS-CoV-2-positive nasopharyngeal swab samples from two testing periods, before (n = 288, using only Variants I) and after (n = 77, using both Variants I and Variants II) the appearance of Omicron. The Variants I assay allowed correct identification for Alpha (37/37), Beta/Gamma (28/30), or Delta (220/221) variant-positive samples. The combination of the Variants I and Variants II assays allowed correct identification for 61/77 Omicron variant-positive samples. While 16 samples had the K417N mutation undetected with the Variants II assay, 74/77 samples had both ΔH69/V70 and N501Y mutations detected with the Variants I assay. If considering only the results by the Variants I assay, 6 (2 Beta variant positive, 1 Delta variant positive, and 3 Omicron variant positive) of 365 samples tested in total provided incorrect identification. We showed that the Variants I assay alone might be more suitable than both the Variants I and Variants II assays to identify currently circulating SARS-CoV-2 variants. Inclusion of additional variant-specific mutations should be expected in the development of future assays. IMPORTANCE Omicron variants of SARS-CoV-2 pose more important public health concerns than the previously circulating Alpha or Delta variants, particularly regarding the efficacy of anti-SARS-CoV-2 vaccines and therapeutics. Precise identification of these variants highly requires performant PCR-based assays that allow us to reduce the reliance on NGS-based assays, which remain the reference method in this topic. While the current epidemiological SARS-CoV-2 pandemic context suggests that PCR assays such as the Seegene Variants II may be dispensable, we took advantage of NGS data obtained in this study to show that the array of SARS-CoV-2 spike protein mutations in the Seegene Variants II assay may be suboptimal. This reinforces the concept that initially developed PCR assays for SARS-CoV-2 variant detection could be no longer helpful if the SARS-CoV-2 pandemic evolves to newly emerging variants.

3.
Vaccines (Basel) ; 10(11)2022 Oct 31.
Article in English | MEDLINE | ID: covidwho-2099897

ABSTRACT

At the onset of the SARS-CoV-2 pandemic, individual and social measures were strengthened through restrictive non-pharmaceutical interventions, labelled with the term "lockdown". In Italy, there were two lockdowns (9 March 2020-3 May 2020 and 3 November 2020-27 March 2021). As part of preventive measures, healthcare workers and the administrative staff population of Policlinico A. Gemelli underwent nasopharyngeal swab tests from 1 March 2020 to 9 February 2022, a long time interval that includes the two aforementioned lockdowns. The population included 8958 people from 1 March 2020 to 31 December 2020; 8981 people from 1 January 2021 to 31 December 2021; and 8981 people from 1 January 2022 to 9 February 2022. We then analysed pseudo-anonymized data, using a retrospective observational approach to evaluate the impact of the lockdown on the incidence of SARS-CoV-2 infections within the population. Given the 14 day contagious period, the swab positivity rate (SPR) among the staff decreased significantly at the end of the first lockdown, every day prior to 18 May 2020, by 0.093 (p < 0.0001, CI = (-0.138--0.047)). After the fourteenth day post the end of the first lockdown (18 May 2020), the SPR increased daily at a rate of 0.024 (p < 0.0001, 95% CI = (0.013-0.034)). In addition, the SPR appeared to increase significantly every day prior to 17 November 2020 by 0.024 (p < 0.0001, CI = (0.013-0.034)). After the fourteenth day post the start of the second lockdown (17 November 2020), the SPR decreased daily at a rate of 0.039 (p < 0.0001, 95% CI = (-0.050--0.027)). These data demonstrate that, in our Institution, the lockdowns helped to both protect healthcare workers and maintain adequate standards of care for COVID and non-COVID patients for the duration of the state of emergency in Italy.

4.
Microbiol Spectr ; 10(4): e0099022, 2022 08 31.
Article in English | MEDLINE | ID: covidwho-1938016

ABSTRACT

The Omicron (B.1.1.529) variant of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the last variant of concern (VOC) identified to date. Compared to whole-genome or gene-specific sequencing methods, reverse-transcription PCR assays may be a simpler approach to study VOCs. We used a point-of-care COVID-19 diagnostic PCR assay to detect the Omicron SARS-CoV-2 variant in the respiratory tract samples of COVID-19 patients who had tested positive for SARS-CoV-2 RNA between April 2021 and January 2022. Sequencing analyses had shown that 87 samples were positive for the Omicron variant and 43 samples were positive for a non-Omicron variant (Delta, 18 samples; Alpha, 13 samples; Gamma, 10 samples; Beta, 1 sample; or Epsilon, 1 sample). According to results by the PCR assay, whose primers anneal a nucleocapsid (N) gene region that comprises the E31/R32/S33 deletion (also termed the del31/33 mutation), we found that N gene target failure/dropout (i.e., a negative/low result) occurred in 86 (98.8%) of 87 Omicron variant-positive samples tested. These results were assessed in relation to those of the spike (S) gene, which expectedly, was detected in all (100%) 130 samples. A total of 43 (100%) of 43 Delta, Alpha, Gamma, Beta, or Epsilon variant-positive samples had a positive result with the N gene. Importantly, in 86 of 87 Omicron variant-positive samples, the del31/33 mutation was detected together with a P13L mutation, which was, instead, detected alone in the Omicron variant-positive sample that had a positive N-gene result. IMPORTANCE Rapid detection of the Omicron SARS-CoV-2 variant in patients' respiratory tract samples may influence therapeutic choices, because this variant is known to escape from certain monoclonal antibodies. Our findings strengthen the importance of manufacturers' efforts to improve the existing COVID-19 diagnostic PCR assays and/or to develop novel variant-specific PCR assays. Furthermore, our findings show that only a small fraction of SARS-CoV-2-positive samples may require whole-genome sequencing analysis, which is still crucial to validate PCR assay results. We acknowledge that the emergence of novel variants containing mutations outside the PCR assay target region could, however, allow an assay to work as per specifications without being able to identify a SARS-CoV-2-positive sample as a variant. Future work and more experience in this topic will help to reduce the risk of misidentification of SARS-CoV-2 variants that is unavoidable when using the current PCR assays.


Subject(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnosis , COVID-19 Testing , Humans , Mutation , Polymerase Chain Reaction , RNA, Viral/analysis , RNA, Viral/genetics , SARS-CoV-2/genetics , Sensitivity and Specificity
5.
Diagnostics (Basel) ; 12(6)2022 May 28.
Article in English | MEDLINE | ID: covidwho-1869512

ABSTRACT

We used nasopharyngeal swab samples of patients with a symptomatic (n = 82) or asymptomatic (n = 20) coronavirus disease 2019 (COVID-19) diagnosis to assess the ability of antigen detection tests to infer active (potentially transmissible) or inactive (potentially non-transmissible) infection by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Using the subgenomic RNA (sgRNA) as an active replication marker of SARS-CoV-2, 48 (76.2%), 56 (88.9%), and 63 (100%) of 63 samples with sgRNA positive results tested positive with the SD BIOSENSOR STANDARD Q COVID-19 Ag (Standard Q), the SD BIOSENSOR STANDARD F COVID-19 Ag FIA (Standard F), or the Fujirebio LUMIPULSE G SARS-CoV-2 Ag (Lumipulse) assay, respectively. Conversely, 37 (94.9%), 29 (74.4%), and 7 (17.9%) of 39 samples with sgRNA negative results tested negative with Standard Q, Standard F, or Lumipulse, respectively. Stratifying results by the number of days of symptoms before testing revealed that most antigen positive/sgRNA positive results were among samples tested at 2-7 days regardless of the assay used. Conversely, most antigen negative/sgRNA negative results were among samples tested at 16-30 days only when Standard Q or Standard F were used. In conclusion, based on our findings, a negative antigen test, especially with the Lumipulse assay, or a positive antigen test, especially with the Standard F assay, may suggest, respectively, the absence or presence of replication-competent SARS-CoV-2.

6.
Am J Perinatol ; 2022 May 17.
Article in English | MEDLINE | ID: covidwho-1735323

ABSTRACT

OBJECTIVE: The extent of vertical transmission (VT) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from mothers their fetuses or neonates is still uncertain. We aimed to determine the incidence of VT. STUDY DESIGN: In this prospective cohort study. All mother diagnosed with SARS-CoV-2 infection at the time of delivery or up to 1 week prior and their neonates, managed in a tertiary referral hospital for pregnancy complicated by coronavirus disease 2019 (COVID-19) in Rome, from April 2 to December 22, 2020, were included. Maternal infection was defined as nasopharyngeal swab test results positive for SARS-CoV-2 reverse transcription-polymerase chain reaction (RT-PCR). Biological samples were collected before, at, and after delivery to test positivity for SARS-CoV-2 RT-PCR and anti-SARS-CoV-2-specific antibodies. RESULTS: The cohort included 95 women and 96 neonates with documented SARS-CoV-2 test results. Four neonates (4.2%) tested positive. The incidence of VT, according to the guidance criteria for diagnosing perinatal SARS-CoV-2 infection, was 5.2%. Neonatal symptoms were due to prematurity or fetal distress: symptomatic infants had lower median (min-max) gestational age, 38.1 (29.3-40.6) versus 39.3 (33.9-41.9) weeks (p = 0.036), and 1-minute and 5-minute Apgar scores, 9 (3-9) versus 9 (7-10) (p = 0.036) and 10 (6-10) versus 10 (8-10) (p = 0.012), respectively, than asymptomatic infants and needed more frequent assistance in the delivery room (22.2 vs 2.5%; p = 0.008). Only six (7.1%) neonates had anti-SARS-CoV-2-specific antibodies, despite the ongoing maternal infection. CONCLUSION: The incidence of VT is low as is the detection of specific anti-SARS-CoV-2 antibodies in cord blood when infection is contracted late in pregnancy. This would suggest poor protection of infants against horizontal transmission of the virus. KEY POINTS: · VT of SARS-CoV-2 from pregnant mothers to fetuses or neonates can be possible.. · In this prospective cohort study, the incidence of VT is found to be 5.2%.. · VT is low but exists..

7.
Diagnostics (Basel) ; 11(7)2021 Jul 05.
Article in English | MEDLINE | ID: covidwho-1295790

ABSTRACT

BACKGROUND: SARS-CoV-2 antigen detection has currently expanded the testing capacity for COVID-19, which yet relies on the SARS-CoV-2 RNA RT-PCR amplification. OBJECTIVES: To report on a COVID-19 testing algorithm from a tertiary care hospital emergency department (ED) that combines both antigen (performed on the ED) and RT-PCR (performed outside the ED) testing. METHODS: Between December 2020 and January 2021, in a priori designated, spatially separated COVID-19 or non-COVID-19 ED areas, respectively, symptomatic or asymptomatic patients received SARS-CoV-2 antigen testing on nasopharyngeal swab samples. Antigen results were promptly accessible to guide subsequent, outside performed confirmatory (RT-PCR) testing. RESULTS: Overall, 1083 (100%) of 1083 samples in the COVID-19 area and 1815 (49.4%) of 3670 samples in the non-COVID-19 area had antigen results that required confirmation by RT-PCR. Antigen positivity rates were 12.4% (134/1083) and 3.7% (66/1815), respectively. Compared to RT-PCR testing results, sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of antigen testing were, respectively, 68.0%, 98.3%, 88.8%, and 94.1% in the COVID-19 area, and 41.9%, 97.3%, 27.3%, and 98.6% in non-COVID-19 area. Practically, RT-PCR tests were avoided in 50.6% (1855/3670) of non-COVID-19 area samples (all antigen negative) from patients who, otherwise, would have needed antigen result confirmation. CONCLUSIONS: Our algorithm had value to preserve RT-PCR from avoidable usage and, importantly, to save time, which translated into a timely RT-PCR result availability in the COVID-19 area.

SELECTION OF CITATIONS
SEARCH DETAIL